Switchyard surge arrestors |
|
|
Depend on quantity |
|
|
Negotiable |
|
|
To be advised |
|
|
T/T or L/C |
Introduction
- This is the protective equipment from failures caused by surge or lightning striking
Applications.
- Data, Coaxial, Communication signal Surge protection
- Phone, PLC, RTU, SCADA, Analog signal Surge protection
- Security, surveillance, fire equipment surge protection
- CCTV, the antenna signal surge protection
Specifications
|
Item
|
EB4CH-2DSP
|
EB4CH-DSP
|
| Specification |
Channel number : 2 coaxials & 2 signals Display : 4-channel surge event counter |
4 signals |
| Rated voltage/ current : DC 24V/100mA | ||
| MCOV : DC36V | ||
| Nominal Discharge Current : 10A | ||
| Insulation resistance (Uc) : more than 10MOhm | ||
|
Features Protector for |
DC loop resistance : less | |
| Capacitance (at 1kHz, 1Vrms) : 1less than 1.5nF | ||
| Insertion loss (at-3dB) : DC-100kHz | ||
| Return Loss : 0.2dB | ||
| Protection mode : Line-Line, Line-Ground | ||
|
Voltage protection (C2 Category) (at 20kV/ 10kA voltage 1.2/50µs, current8/20µs): less than 100V |
||
| Max. Discharge current (CM : 25kA(current 8/20µs) : 25kA | ||
| Responese time tA (at 10kV/µs) : less than 5nsec | ||
| Operation features : Alarming and indicating, self-diagnosiss, surge event logger, equipment state display | ||
|
Features Protector for Only EB4CH-2DSP |
DC loop resistance : less than 1 ohm | |
| Capacitance (at 1kHz, 1Vrms) : less than 0.5nF | ||
| Isertion loss (at-3dB) : DC -100kHz | ||
| Protection mode : Line-Ground | ||
|
Voltage protection (C2 Category) (at 20kV/10kA voltage 1.2/50µs, current 8/20µs) : less than 100v |
||
| Max. Discharge current (CM : 25kA(current 8/20µs) : 25kA | ||
| Responese time tA (at 10kV/µs) : less than 5nsec | ||
| Operation features : Alarming and indicating, self-diagnosiss, surge event logger, equipment state display | ||
| Option | Interface : Even Data Logger, Remote-Controlling and Monitoring 250EA | |