1. General requirements
1-1. The specification is applied to tact switch used in the circuit of low current.
1-2. Operating temperature : -40℃ to +85℃
1-3. Storage temperature : -40℃ to +85℃
1-4. Test conditions : Temperature - 5℃ to 35℃,
: Relative humidity - 45%RH to 85%RH
: Atmospheric pressure - 86kPa to 106kPa (860mbar ~ 1060mbar)
If there is an objection to a judgment, the following conditions shall be appled
◆Temperature : 20±2℃, Relative humidity:65±5%RH, Atmospheric pressure: 86kPa to 106kPa (860mbar ~ 1060mbar)
2. Appearance & Dimensions : Refer to the drawing
3. Electrical arrangement : single pole, single throw
(The two terminlas are either connected together or disconnected from each other)
4. Arrangement of operation : Tactile feed-back
5. Maximum rating : D.C 12V, 50mA
6. Electrical requirements
6-1. Contact resistance
Applying static load twice the actuating force to the center of the Stem, measurements shall be made with a 1 kHz small-current contact resistance meter.
100mΩ Max.
6-2. Insulation resistance
Measurements shall be made following application of D.C 100V potential between terminals and between individual terminals and frame for 1 minute.
100MΩ Min.
6-3. Dielectric withstanding voltage
A.C 250V(50Hz to 60Hz)is applied between terminals and between terminals and frame for 1 minute.
There shall be no breakdown
6-4. Bounce
Lightly pushing the center of the Stem at a rate of 3 operations/sec. Bounce shall be tested when "ON" and " OFF"
10 ms Max.